English | Español

Sankosha 3Y06-Series Gas Tube Arresters

Applications:
  • Cable Telephony Products
  • Modems/Cable Modems
  • Broadband/CATV/Coaxial Protectors
  • xDSL Modems and Peripherals
  • Building Entry/Outside Plant
  • Transient Voltage Surge Suppression
  • Features:
  • UL 497B Recognized (File E140906)
  • High Surge Current Rating
  • Non-Radioactive
  • RoHS Compliant (100% Lead-Free)
  • ISO 9001 Certified
  • Low Capacitance
  • Part
    Number
    DC Breakdown Voltage(1)
    (L1-E)(L2-E)
    Impulse Breakdown Voltage
    (L1-E)(L2-E)
    Insulation Resistance
    (2)
    Capac-itance
    1 MHz
    pF
    DC Holdover Voltage
    V(3)
    Impulse Life 10/1000μs 200A Impulse Discharge Current
    8/20μs
    10 Times(4)
    AC
    Discharge Current
    50Hz
    (L1+L2-E)
    1 Second
    100V/s 1kV/μs
    3Y06-90 90V ≤ 850V ≥ 10,000 ≤ 3.0pF ≤ 52V 100 Times 5 kA 5A, 5 Times
    3Y06-230 230V ≤ 700V ≥ 10,000 ≤ 3.0pF ≤ 135V 100 Times 10 kA 10A, 5 Times
    3Y06-350 350V ≤ 750V ≥ 10,000 ≤ 3.0pF ≤ 150V 100 Times 5 kA 5A, 5 Times
    Notes:
    1. DC Breakdown Voltage Ranges are ± 20%
    2. Insulation Resistance measured at:
            DC 50V for the 3Y06-90
            DC 100V for the 3Y06-230 and 3Y06-350
    3. DC Holdover Voltage measured in accordance with the ITU-T K.12 or the IEEE C62.31-1987 Test Circuit
    4. 5 times each polarity
     
    Home      Arresters      Grounding      Contact Us      About Sankosha
    Sankosha U.S.A., Inc., 406 Amapola Avenue, Suite 135, Torrance, CA 90501
    Toll Free: 888.711.2436 Ph: 310.320.1661 Fax: 310.618.6869 Email: sales@sankosha-usa.com